IOMF (I/O Multifunction)

Each I/O multifunction (IOMF) CRU contains these components:

A

service processor (SP)

A

power supply

Three

SCSI controllers

Location in OSM Tree: System > Group > Module > IOMF

Slot Location: IOMF CRUs are located in slots 50 and 55 in I/O enclosures (service side).

Example: IOMF (2.1.50)

Attributes

IOMF

Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.

Values

Service State

Physical

A code that identifies the generation of the component. Hardware revision codes are
used for tracking components.

Hardware Revision

Identifies the manufacturer of the component.

Manufacturer

The part number of the component that was assigned in manufacturing. Use part
numbers for identifying and ordering parts.

Part Number

Whether the component is powered on.

Values

Power State

A unique serial number that identifies the component. Track IDs are used for tracking
components.

Track ID

Logical

The current voltage of the Fan CRU.

Fan Voltage

The voltage of the Main Rail, which supplies power to the CRU from its own power
supply

Main Rail Voltage

Which, if any, ServerNet router ports on this CRU are disabled. OSM actions to
disable or enable a ServerNet port are performed as directed by OSM alarm repair
actions.

Disabled ServerNet Ports

The voltage of the SCSI-Y path, the path configured for mirrored disks on a system.

SCSI-Y Voltage

The minimum voltage (39.6 volts) that must be available to power the CRU.

Rail Minimum Voltage

The voltage of the SCSI-X path, the primary path used for disks on a system.

SCSI-X Voltage

The maximum voltage limit (60 volts) for the CRU.

Rail Maximum Voltage

The voltage of the Other Rail, which connects the PMF/IOMF CRU to the other power
supply in the enclosure (to provide power in the event of a problem with the Main
Rail power supply).

Other Rail Voltage

Storage ASIC

The status of the storage ASIC in the CRU.
Values: Initialized, Uninitialized, Unknown

Initialization State

Actions

Disable ServerNet Port

Disables the specified ServerNet router port on this CRU. Perform this action only as directed by OSM alarm repair