beautypg.com

Teledyne LeCroy Merlin II - Users Manual User Manual

Page 43

background image

33

Merlin II Protocol Analyzer User’s Manual

CATC

SW Version 2.50

4

Analyzer is connected to the host machine and is an idle mode.

5

Analyzer is synchronized to a piconet with master device that has BD_Address
008037322FD9.

6

Analyzer is performing an inquiry (BT Neighborhood).

7

Analyzer is in the process of synchronizing to a piconet with slave device that
has BD_Address 008037322FD8. The analyzer is set to use the 'Page Sync &
Record' synchronization method, with master address set to 'any.

8

Analyzer is in the process of synchronizing to a piconet with master device
that has BD_Address 008037322FD9. No trigger connection received yet.

9

Analyzer is in the process of synchronizing to a piconet with master device that
has BD_Address 0080371637B7. The analyzer is set to use either of the
synchronization methods (if the 'Page Sync & Record' synchronization method
is used the master address is set to 0080371637B7).

10

Analyzer is recording the traffic of the piconet with master device that has
BD_Address 008037322FD9. The trigger condition was received.

11

Analyzer has finished uploading the recorded traffic.

As recording progresses, the Progress Indicator changes to reflect the
recording progress graphically:

In the Progress Indicator, a black vertical line illustrates the location of the
Trigger Position you selected in Recording Options.

Pre-Trigger progress is displayed in the field to the left of the Trigger

Position in the before-Trigger color specified in the Display Options.

When the Trigger Position is reached, the progress indicator wiggles as it

waits for the trigger.

After the trigger occurs, the field to the right of the Trigger Position fills

in the post-Trigger color specified in the Display Options.

When recording is complete, the upper half of the progress indicator fills

in white, indicating the progress of the data upload to the host computer.

You should be aware of two exceptional conditions:

If a Trigger Event occurs during the before-Trigger recording, the
before-Trigger color changes to the after-Trigger color to indicate that not all
the expected data was recorded pre-Trigger.

When you click Stop before or after a Trigger Event, the Progress Bar adjusts
accordingly to begin uploading the most recently recorded data.

The Progress Bar fills with color in proportion to the specified size and
actual rate at which the hardware is writing and reading the recording
memory. However, the Progress Indicator is normalized to fill the space