9 decoding via the profiles toolbar, 10 changing protocol assignments – Teledyne LeCroy Merlin II - Users Manual User Manual
Page 145
135
Merlin II Protocol Analyzer User’s Manual
CATC
SW Version 2.50
•
Left-click the small downward pointing arrow in
the message/protocol header
•
Double-click a message/protocol header
•
Left-click the message/protocol header and choose "Expand Transaction"
from the short-cut menu
10.9 Decoding via the Profiles Toolbar
The Profiles toolbar presents buttons that represent profiles. The Profiles
buttons do not represent an additional set of decodes; rather, they represent
shortcuts for the existing decodes. By clicking a Profiles button, the
analyzer software will automatically depress the protocol buttons needed to
decode all of the protocols associated with the selected Profile - for
example, RFCOMM, PPP, or IP.
To display the Profiles toolbar, select View > Toolbars > Profiles.
10.10 Changing Protocol Assignments
If a sequence of messages is assigned the wrong protocol, errors will
display. To change or remove a protocol assignment, you will need to
access the Assignment menu and issue an Add Assignment command.
Step 1
Click
to display L2CAP messages.
Note
You need to view L2CAP Messages in order to have access to the "A" field that
permits reassigning protocols.
Step 2
Scroll through the trace until you have located an L2CAP
message with a field marked "A."