1) sa5/sa6/ss type (2) sa7 type, Sa5/sa6/ss type (2) sa7 type – IAI America RCP2-CF User Manual
Page 80

60
6.1.1
Relationship of Push Force at Standstill and Current-Limiting Value
When performing operation in the push & hold mode, enter the current-limiting value (%) in the push column of
the position-data table.
Determine the current-limiting value (%) from the push force to be applied to the load at standstill.
The graphs below illustrate the relationship of push force at standstill and current-limiting value for each actuator
type:
Slider type
(1) SA5/SA6/SS type
(2) SA7 type
Note: The accuracy of push force at standstill is not guaranteed. The above graphs are provided for
reference purposes only. If the push force is too small, malfunction may occur during push &
hold operation due to slide resistance, etc., so exercise caution.
The maximum current-limiting value is shown in the above graphs. The minimum value is 20%.
Low-speed type
Low-speed type
(Lead: 3 mm)
(Lead: 4 mm)
Push force (N)
Push force (N)
Push force (N)
Current-limiting value (ratio in %)
Current-limiting value (ratio in %)
Medium-speed type
Medium-speed type
(Lead: 6 mm)
(Lead: 8 mm)
Push force (N)
Push force (N)
Push force (N)
High-speed type
High-speed type
(Lead: 12 mm)
(Lead: 16 mm)
Current-limiting value (ratio in %)
Current-limiting value (ratio in %)
Current-limiting value (ratio in %)
Current-limiting value (ratio in %)