beautypg.com

Pio pattern 5 [4 points] (air cylinder), Lower stage upper stage blue 3 brown 1 – IAI America RCP2-CF User Manual

Page 57

background image

37

 PIO pattern 5 [4 points] (air cylinder)




































Note: The factory-set PIO pattern is [Conventional], so change the value in parameter No. 25 to “5.”

The pause signal may be disabled using parameter No. 15.









Note: When performing a continuity check of the flat cable, pay due attention not to expand the

female pins in the connector. It may cause contact failure and disable normal operation of the
controller.

1A P24

2A N

3A ST0

4A ST1

5A ST2

6A ST3

7A

8A *STP

9A

10A

11A

12A RES

13A

1B

2B

3B PE0

4B PE1

5B PE2

6B PE3

7B ZONE

8B

9B PEND

10B HEND

11B

*EMGS

Available on “RCP2-C.” Not used on “RCP2-CG.”

12B

13B *ALM

Brown 1

Red 1

Orange 1

Yellow 1

Green 1

Blue 1

Purple 1

Gray 1

White 1

Black 1

Brown 2

Red 2

Orange 2

Yellow 2

Green 2

Blue 2

Purple 2

Gray 2

White 2

Black 2

Brown 3

Red 3

Orange 3

Yellow 3

Green 3

Blue 3

Controller end
PIO (signal abbreviation)

Output s

ide

+24 [V]

0 [V]

Rear end move

Front end move

Intermediate point

1 move

Intermediate point

2 move


Pause








Reset





Rear end complete

Front end complete
Intermediate point

1 complete

Intermediate point

2 complete

Zone output

Position complete

Home return

completion

Emergency stop

Alarm

Inpu

t side

Upper
stage

Lower
stage

(Note) *STP, *ALM and *EMGS are based on the negative logic.

Host system end

Lower stage

Upper stage

Blue 3

Brown 1

13A


1A

13B


1B