9. Controlling Multiple Controllers via Serial Communication

This section explains the connection method to be used when multiple controllers are controlled using the PC or
PLC’s communication module as the host.

9.1 Basic

Specifications

Specification item Description

Maximum number of units that can be connected

16 units

Maximum cable length

100 m or less

Terminal resistor

220

Provide a communication path via bus connection and be sure to provide a terminal resistor at the end.

9.2 Connection

Example






































Note: Do not connect the teaching pendant and PC at the same time.

If both are connected at the same time, a communication error (message level) will occur.

PC, etc.

Teaching pendant

Optional

Cable length: 5

PC software

Optional

RS232C cross cable
(Provided by the user)

Components:

SIO converter (with built-in terminal resistor)
Vertical type
Horizontal type

FG
0V
24V

Input power

supply

Controller power

supply

Terminal resistor
R = 220

Controller link cable

ADRS switch: 0

Controller 1

ADRS switch: 1

Controller 2

ADRS switch: n-1

Controller n

E-Con connector (AMP 4-1473562-4: housing color green)

E-Con connector (AMP 3-1473562-4: housing color orange)

Junction (AMP 5-1473574-4)

Green Green

Green

(Note) External equipment communication

cable cannot be
used for connection to a PC, PLC, etc.