background image

83

7.2.4

Operation Timings at PIO Pattern = “5: [4 Points]”


(Example)

When “30 mm” is set as the target position in position No. 0 (Rear end), and the home
position is not yet established.

[Operation with the standard controller]





















[Operation with the absolute-specification controller]





















Note: With the absolute-specification controller, the actuator will not move to the target position if the

set position is “other than 0.”

Make sure the PLC can recognize that the actuator is stopped at the home position.

Rear end move ST0

Position complete REND

Home return completion HEND

Rear end complete PE0

Actuator movement

Mechanical end

Home position

Stops after moving to
the 30-mm position.

Mechanical end

Stops at the home position.

(Does not move to the 30-mm position.)

Rear end move ST0

Position complete REND

Home return completion HEND

Actuator movement