beautypg.com

Wiring, 1 configuration, Configuration – IAI America RCP2-CF User Manual

Page 38

background image

18

4. Wiring

4.1

Internal Drive-Power Cutoff Relay Type (RCP2-C, RCP2-CF)

4.1.1 Configuration













































Note: Connect one end of the EMG switch to the 24-V output of the input power supply and the

other end to the S1 terminal. Also short the S2 and EMG terminals using a jumper wire.

S1
S2
MPI
MPO
24V
N
EMG

Standard teaching pendant

Optional

Cable length: 5 m

External unit

Cable length: 2 m
Cable length: 5 m

Optional

PC

PC software

Optional

External EMG switch

Input power supply
24V

24 VDC

0

Host system

Supplied flat

cable

Cable length: 2 m

ROBO cylinder

Cable length: 5 m

Optional

* If the PLC is not used,

disable the servo ON
input and pause input
using the applicable
parameters.

Do not connect or disconnect
the connectors while the
power is on, except for the
communication port
connector (SIO). To connect
or disconnect the SIO, do so
after turning off the PORT
switch. Failure to do so may
result in breakdown.

This manual is related to the following products: