17

3.4

Heat Radiation and Installation


Design the control panel size, controller layout and cooling method in such a way that the temperature around
the controller will not exceed 40

C.


Install the controller vertically on a wall, as shown below. Since cooling is provided by way of natural convection,
always observe this installation direction and provide a minimum clearance of 50 mm above and below the
controller to ensure sufficient natural airflows.

When installing multiple controllers side by side, providing a ventilation fan or fans above the controllers will help
maintain a uniform temperature around the controllers.

Keep the front panel of the controller away from the wall (enclosure) by at least 95 mm.


















Regardless of whether your system consists of a single controller or multiple controllers, provide sufficient
clearances around each controller so that it can be installed/removed easily.

In the case of the large-capacity type, extra space is required to release the exhaust heat from the radiating fan.
Therefore, provide a clearance of 15 mm or more for this controller type.

Fan

50 mm or more

50 mm or more

Airflow

95 mm

or more