beautypg.com

IAI America RCP2-CF User Manual

Page 150

background image

130

Code Error

name

Cause/Action

F8 Damaged

nonvolatile

memory

Abnormal data was detected during the nonvolatile memory check after
starting.
Cause: [1] Faulty nonvolatile memory

[2] The memory has been rewritten more than 100,000 times.

(The nominal rewrite limit of the nonvolatile memory is
around 100,000 times.)

Action: If the alarm generates again after reconnecting the power,

please contact IAI.

FA

CPU error

The CPU is not operating properly.
Cause: [1] Faulty

CPU

[2] Malfunction due to noise

Action: If the alarm generates again after reconnecting the power,

please contact IAI.

FB

FPGA error

The FPGA (gate array) of the absolute-specification controller is not
operating properly.
Cause: [1] Malfunction due to the effect of noise, etc.
[2]

Faulty

FPGA

[3] Defective board installation inside the controller

Action: Reconnect the power.

If the error persists, investigate possible noise sources.

If the cause cannot be specified, please contact IAI.


This manual is related to the following products: