beautypg.com

IAI America RCP2-CF User Manual

Page 108

background image

88


Position-data table (Field(s) within thick line must be entered.)

No. Position

Speed

Acceleration/

deceleration

Push Positioning

band

Acceleration

only MAX

0

* * * * * *

1

250

200

0.3 0 0.1 0

2

100

100

0.3 0 0.1 0





















T1:

6 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)

Each command position must be input after the position complete output has turned ON for the movement to the
previous position.

Note: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.

The start signal must be turned OFF with the confirmation that the moving output has turned
ON (position complete output has turned OFF) while the start signal remains ON.

If the start input remains ON as shown below, the position complete output will not turn ON
even when the actuator movement is completed.














Command position


Start

Position complete

Moving

Completed position

Actuator movement

Speed

Position 1

Position 2

Position 1

Note Note Note

Position 1

Position 2

Position 1

T

1

T

1

T

1

T

1

Start

Position complete

Moving


Actuator

1 msec or less

Movement is complete.