IAI America RCP2-CF User Manual
Page 108
88
Position-data table (Field(s) within thick line must be entered.)
No. Position
Speed
Acceleration/
deceleration
Push Positioning
band
Acceleration
only MAX
0
* * * * * *
1
250
200
0.3 0 0.1 0
2
100
100
0.3 0 0.1 0
T1:
6 msec or more; time after selecting/entering a command position until the start input turns ON
(The scan time of the host controller must be considered.)
Each command position must be input after the position complete output has turned ON for the movement to the
previous position.
Note: When the start signal turns ON, the position complete output will turn OFF and the moving
output will turn ON.
The start signal must be turned OFF with the confirmation that the moving output has turned
ON (position complete output has turned OFF) while the start signal remains ON.
If the start input remains ON as shown below, the position complete output will not turn ON
even when the actuator movement is completed.
Command position
Start
Position complete
Moving
Completed position
Actuator movement
Speed
Position 1
Position 2
Position 1
Note Note Note
Position 1
Position 2
Position 1
T
1
T
1
T
1
T
1
Start
Position complete
Moving
Actuator
1 msec or less
Movement is complete.