Parameters, 1 parameter classification, 2 parameter table – IAI America RCP2-CF User Manual

Page 129: Parameter classification, Parameter table

background image

109

8. Parameters

8.1 Parameter

Classification

Parameters are classified into four types according to their content.
Category:

a: Parameter relating to the actuator stroke range
b: Parameter relating to the actuator operating characteristics
c: Parameter relating to the external interface
d: Servo gain adjustment


8.2 Parameter

Table

No.

Category

Name

Unit

Default factory setting

1

a

Zone boundary 1+

mm

Effective actuator length

2

a

Zone boundary 1–

mm

Effective actuator length

3

a

Soft limit+

mm

Effective actuator length

4

a

Soft limit–

mm

Effective actuator length

5 a

Home return direction
(0: [Reverse]/1: [Forward])

-

(In accordance with the specification at the time
of order)

6

b

Push & hold stop judgment period

msec

255

7

d

Servo gain number

-

Set individually in accordance with the actuator
characteristics.

8 b

Default

speed

mm/sec

Set individually in accordance with the actuator
characteristics.

9 b

Default

acceleration/deceleration

G

Set individually in accordance with the actuator
characteristics.

10

b

Default positioning band (in-position)

mm

0.10

11

b

Default acceleration only MAX flag

-

0

12 b

Current-limiting value at standstill during
positioning

%

Set individually in accordance with the actuator
characteristics.

13

b

Current-limiting value during home return

%

Set individually in accordance with the actuator
characteristics.

14

(Reserved for future expansion)

15 c

Pause input disable selection
(0: [Enable]/1: [Disable])

- 0

16

c

Serial communication speed

bps

38400

17

c

Minimum delay time for slave transmitter activation

msec

5

18

(Reserved for future expansion)

19

(Reserved for future expansion)

20

(Reserved for future expansion)

21 c

Servo ON input disable selection
(0: [Enable]/1: [Disable])

- 1

22

a

Home return offset

mm

Set individually in accordance with the actuator
characteristics.

23

a

Zone boundary 2+

mm

Effective actuator length

24

a

Zone boundary 2–

mm

Effective actuator length

25

c

PIO pattern selection

-

0: [Conventional]

26

b

PIO jog speed

mm/sec

100

27

c

Movement command type (0: [Level]/1: [Edge])

-

0: [Level]

28 b

Direction of excitation phase signal detection
(0: [Reverse]/1: [Forward])

-

Set individually in accordance with the actuator
characteristics.

(Note) The numbers are displayed on the PC software screen but not on the teaching pendant. The category

codes are provided only for convenience and not displayed on either the PC software screen or
teaching pendant.