Section 3: GUIDED TOUR of the HARDWARE 31
Parallel Control Port
The parallel control port has 8 inputs and 8 outputs that can be used in a variety of ways. For
instance, in AAC, AAC‐LD, Layer 3 and certain Layer 2 modes, these contact closures can
communicate between two Zephyr Xstreams. By grounding an input on the local Xstream, you
would therefore cause current to flow into the corresponding output, at the far end unit. These
can also be used for local control and to monitor local status see Section 11 has additional
information on the use of this port.
Z
ZEPHYR CLASSIC VS. XSTREAM COMPARISON!
The original Zephyr has only four inputs and outputs numbered 0-3 while the Xstream has 8
inputs 0-7. The four inputs and outputs of the Zephyr will communicate with the first four
inputs and outputs of the Xstream (i.e. 0-3)
PIN
FUNCTION
1
+5 Volts DC 400 mA max
2* Output
0
3*
Output 1
4* Output
2
5*
Output 3
6 Output
4
7
Output 5
8 Output
6
9
Output 7
10 No
Connection
11
No Connection
12 No
Connection
13
No Connection
14* Input
0
15* Input 1
16* Input
2
17* Input 3
18 Input
4
19
Input 5
20 Input
6
21
Input 7
22 Not
Connected
23
Not Connected
24 Not
Connected
25
Ground
*
These pins are compatible with the
corresponding input/outputs of the
Zephyr.
NOTE: Pin 1 is connected directly to the +5 volt power supply. Failure to limit current
draw on this pin could cause hardware damage or system instability.