Section 13: Deep Tech Information and Troubleshooting 271
h
HOT TIP!
If you don't know a valid DNS (domain name sever) IP address, you can still update your
Xstream from the Telos ftp site by obtaining the current IP address of the Telos FTP server as
follows:
1. Go to the MS-DOS command line of the Windows machine (Run " cmd
2000 or Win NT; or Run "command
2. From the command line type "ping ftp.zephyr.com
3. You should receive a reply. If you do not get a reply check with your IT manager for
assistance. The reply will include the current IP address of the Telos FTP server.
4. Enter this IP address as "FTP site" in the Xstream.
Manual Replacement Method (10 Base-T hardware only)
The system’s software is contained within a flash memory SIMM module, similar in size and
form to those used for PC memory. The following directions are for qualified service personnel
only. If you need to change this module, follow the procedure below:
h
HOT TIP!
This method of updating your Xstream will result in losing your Location Setups and Dial
Setups.
1) Remove the top cover as described in Section 13.1.
2) Remove the old software SIMM
• Turn the right side of the unit towards you (the power supply will be away from
you).
• Near the front of the main PC board (PWB) you will see a ribbon cable
connector and a very small PC board (the SIMM module) directly to the right of
it.
• Push gently outward on the two metal catches on either end of the SIMM
module. It should pop toward you.
• Pivot the top of the SIMM module toward you and then lift it out. Note the
grooved notch on the right end.
3) Install the new SIMM module.