Telos Zephyr Xstream User Manual
Page 250

USER’S MANUAL
Section 11: THE WORKS – Detailed Menu Reference 238
Line 1 Conn
Causes this output to go the "true" state whenever Line 2 is in the "Connected"
state (as indicated on the first TEL menu).
Lock A* AND B*
Causes this output to go the "true" state whenever both Lock A and Lock B are
"on" (as indicated on the corresponding front panel LEDs).
Lock A* OR B*
Causes this output to go the "true" state whenever either Lock A or Lock B or
both are in the "on" state (as indicated on the corresponding front panel LEDs).
Lock B*
Causes this output to go the "true" state whenever Lock A is in the "on" state (as
indicated on the corresponding front panel LED).
Lock A*
Causes this output to go the "true" state whenever Lock A is in the "on" state (as
indicated on the corresponding front panel LED).
* Some Xstreams have a "Lock 1" and "Lock 2" LEDs while others have "Lock A" and "Lock B"
LEDs.
End‐to‐End
Causes this output to follow the state of the corresponding Input of a Zephyr to
which it is locked. When no connection is present (or a coding mode is used
that does not support ancillary data), this output will go to the false state.