Telos Zephyr Xstream User Manual
Page 192

USER’S MANUAL
Section 10: APPLICATIONS GUIDE 180
Zephyr (classic) at far end:
Transmit Mode at Far End:
Set Local Receive Mode to:
Set Local Sample Rate to:
°
L3 DUAL or L3 MONO
L3 Dual/Mono
32 or 48 kHz
L3 STEREO
L3
32 or 48 kHz
L3 JSTEREO
L3
32 or 48 kHz
G.722 G.722 *
Any
L2 MONO
L2 64
48 kHz
L2 MONO128
L2
48 kHz
°
L2 STEREO or L2 DUAL
L2
48 kHz
L2 JSTEREO
L2
48 kHz
L2 HALF/24
L2 64
+ Any
Sample rates on the two ends must match
* Actual Sample Rate will be 16 kHz regardless of setting
+ Actual Sample Rate will be 24 kHz regardless of setting
°
Name will depend on software version
ZephyrExpress at far end:
Transmit Mode at Far End:
Set Local Receive Mode to:
Set Local Sample Rate to:
L3-DUAL
L3 Dual/Mono
32 or 48 kHz
L3-STEREO
L3
32 or 48 kHz
L3-JOINT
L3
32 or 48 kHz
G.722 G.722 *
Any
L2-MONO64 L2
64
48
kHz
L2-MONO128 L2
48
kHz
L2-DUAL L2
48
kHz
L2-JSTEREO L2
48
kHz
L2-HALF/24 L2
64
+
Any
Sample rates on the two ends must match
* Actual Sample Rate will be 16 kHz regardless of setting
+ Actual Sample Rate will be 24 kHz regardless of setting