beautypg.com

Telos Zephyr Xstream User Manual

Page 186

background image

USER’S MANUAL

Section 10: APPLICATIONS GUIDE 174

When full fidelity is needed in both directions:

Field Unit: AAC‐LD Mono 64 Transmit and AAC 64 Receive. 

Studio Unit: AAC‐LD Mono 64 Transmit and AAC 64 Receive 

Use 32 kHz sample rate for best fidelity or 48 kHz for reduced delay

5

Radio remotes where only POTS is available at the remote location

Best:

Field Unit: Zephyr Xport 

Studio Unit: Zephyr Xstream 

Dial using "Xport" mode 

Radio remotes (Stereo) using a single B channel (1 call)

Good:

Field Unit: AAC J Stereo 64 Transmit and G.722 Receive. 

Studio Unit: G.722 Transmit and AAC 64 Receive. 

Use 32 kHz sample rate. 

When best stereo is needed in both directions:

Field Unit: AAC J Stereo 64 Transmit and AAC 64 Receive. 

Studio Unit: AAC J Stereo 64 Transmit and AAC 64 Receive 

Use 32 kHz sample rate 

NOTE: If a single return feed is required, any other single‐B channel mode (typically AAC‐LD, or 
G.722, see above) can be used in the return direction for improved fidelity or reduced delay.

Radio remotes (Stereo) to two sites using a two B channels (2 calls) with
one return from each.

Good:

Field Unit: AAC J Stereo 64 Transmit and G.722 Receive. 

Studio Units: G.722 Transmit and AAC 64 Receive. 

Use 32 kHz sample rate. 

NOTES: