Section 13: Deep Tech Information and Troubleshooting 278

 
Call Proceeding 

Outgoing call in process; Telco switch has acknowledged the 
call request and is waiting for routing information from 
network. 

 
Outgoing Ring 

Outgoing call in process; far end has acknowledged the call 
and has generated a call alert signal (i.e. it is “ringing”) 

 
Accepting Call 

Zephyr Xstream has accepted an incoming call and is 
waiting for the Telco switch to connect it. 

  
Connected XXX 

All signaling is complete ‐ the voice channel is available for 
use. The number of the incoming call, if available, will be 
displayed. 

 

Disconnecting 

Request to disconnect has been made. Awaiting 
acknowledgment. 

 
Ended 

Request to disconnect has been acknowledged but call tear 
down is complete. 

 
Ring 

An incoming call request has been detected and is being 
processed. If auto ans. (in the TEL menu) is set 
appropriately, the system will answer the call momentarily. 

13.6.2 Using Loop Modes for Troubleshooting

Loop Mode

This item allows the Zephyr Xstream to loop audio through the system. 

• None 

This is the normal operating mode.  None of the loopback paths are turned 
on. Studio Input is sent as send audio, and caller audio is presented at 
Studio Out.

 

• V.35 

This loops the incoming V.35/X.21 Receive data on each V.35/X.21 port back 
out the Xmit data pins on the same port.  NOTE: a valid external V.35 clock 
is required. 

• Audio 

This loops the AES/EBU input (and analog signal inputs after Analog‐to‐
Digital conversion) back to the AES/EBU output (and analog output via the 
Digital‐to‐Analog converter).  With this mode engaged you can make signal 
to noise, THD, and frequency response measurements through the system 
to check the input and output stages.