B-4 Using Services

Note that the string numbers within the quotation marks are
expressed in hexadecimal when used with this command.

To associate a string with the service, use the following
commands:

SET SERVICE

servicename BOT stringnumber

SET SERVICE

servicename EOT stringnumber

where servicename is the name or number of the service and
stringnumber is the number of the string as defined above.
The first command (BOT) adds the specified string to the
beginning of the job, while the second command (EOT) adds
the specified string to the end of the job. A given service can
have both a setup and reset string associated with it.

To clear a string number, type:

CLEAR SERVER STRING

stringnumber

To clear a setup or reset string, set the string number to 1
(the null string):

SET SERVICE

servicename BOT 1

SET SERVICE

servicename EOT 1

Enabling Protocols on a Service

You may enable or disable protocols that can access a given
service with the following commands:

SET SERVICE

name LAT ENABLED

SET SERVICE

name IP ENABLED

SET SERVICE

name NETWARE ENABLED