HCD-E1 Installation & Operation Manual

Chapter 4 - Control from the Supervisory Port

11/01/00 19:23

HCD-E1 Command Set Description

4-15

CLR LOOP

Purpose

Deactivate the specified user-initiated loopback or test.

Syntax
CLR LOOP [loop type], or CLR LP [loop type]

Use

To deactivate a local (L) loopback on the HDSL lines, type:

CLR LOOP L LINE or CLR LP L LINE*

To deactivate a local (L) loopback on the E1 sublink of the local HCD-E1,
type:

CLR LOOP L SL or CLR LP L SL

To deactivate the remote (R) loopback on the E1 sublink of the local
HCD-E1, type:

CLR LOOP R SL or CLR LP R SL

To deactivate a remote (R) loopback on the E1 sublink of the remote
unit, type:

CLR LOOP R R SL or CLR LP R R SL

To deactivate the local (L) loopback on data channel X of local HCD-E1,
type:

CLR LOOP L CH X or CLR LP L CH X

To deactivate the remote (R) loopback on data channel X of local
HCD-E1, type:

CLR LOOP R CH X or CLR LP R CH X

To deactivate the remote (R) loopback on data channel X of remote
HCD-E1, type:

CLR LOOP R R CH X or CLR LP R R CH X

To deactivate the BERT test on data channel X of HCD-E1, type:

CLR LOOP BERT CH X or CLR LP BERT CH X

To deactivate the in-band loopback on data channel X of the remote
unit, type:

CLR LOOP INBAND CH X or CLR LP INBAND CH X

To deactivate a local loopback on the H-RPT, type:

CLR LOOP L HRPT or CLR LP L HRPT*

* These commands are available only from the unit configured as central.

HCD-E1 performs the command and displays the date and time, followed
by the HCD-E1 prompt. The TST LED goes off, if there are no more tests
activated.