beautypg.com

RAD Data comm HCD-E1 User Manual

Page 100

background image

Chapter 4 - Control from the Supervisory Port

HCD-E1

Installation & Operation Manual

4-16

HCD-E1 Command Set Description

11/01/00 19:23

CLR TST

Purpose

Deactivate all the user-initiated tests and loopbacks being activated from this
unit.
Syntax
CLR TST
Use
To deactivate all the user-initiated tests and loopbacks, type:

CLR TST

HCD-E1 performs the command and displays the date and time , followed
by the HCD-E1 prompt. The TST LED goes off.

Note

If no test or loopback is currently activated, HCD-E1 displays ERROR 02 on

the terminal.

DATE

Purpose

Set the date for the HCD-E1 internal real-time clock.
Syntax
DATE
Use
1. Type:

DATE

HCD-E1 sends the entry line for the first parameter:

DAY

= 01

2. If you do not want to change the current value of the parameter, press

to confirm it and continue to the next line, otherwise press F to
increase or B to decrease the displayed values, and then press
to confirm the selected value. HCD-E1 displays the entry line for the
next parameter.

3. Repeat the procedure in step 2 to set the month. HCD-E1 displays the

entry line for the year.

4. Type the four digits of the current year. HCD-E1 displays the entry line

for the week day.

5. Repeat the procedure in step 2 to set the week day, and then press

to end.