RAD Data comm HCD-E1 User Manual
Page 100

Chapter 4 - Control from the Supervisory Port
HCD-E1
Installation & Operation Manual
4-16
HCD-E1 Command Set Description
11/01/00 19:23
CLR TST
Purpose
Deactivate all the user-initiated tests and loopbacks being activated from this
unit.
Syntax
CLR TST
Use
To deactivate all the user-initiated tests and loopbacks, type:
CLR TST
HCD-E1 performs the command and displays the date and time , followed
by the HCD-E1 prompt. The TST LED goes off.
Note
If no test or loopback is currently activated, HCD-E1 displays ERROR 02 on
the terminal.
DATE
Purpose
Set the date for the HCD-E1 internal real-time clock.
Syntax
DATE
Use
1. Type:
DATE
HCD-E1 sends the entry line for the first parameter:
DAY
= 01
2. If you do not want to change the current value of the parameter, press
increase or B to decrease the displayed values, and then press
to confirm the selected value. HCD-E1 displays the entry line for the
next parameter.
3. Repeat the procedure in step 2 to set the month. HCD-E1 displays the
entry line for the year.
4. Type the four digits of the current year. HCD-E1 displays the entry line
for the week day.
5. Repeat the procedure in step 2 to set the week day, and then press