beautypg.com

RAD Data comm HCD-E1 User Manual

Page 113

background image

HCD-E1 Installation & Operation Manual

Chapter 4 - Control from the Supervisory Port

11/01/00 19:23

HCD-E1 Command Set Description

4-29

The codes used by the supported terminals are listed in the following table:

Function

Terminal Type

TV920

VT52

VT100

Freedom100

Freedom220

Clear Screen

1B2A0000

N/A

1B5B324A

1B2A0000

1B5B324A

Cursor Home 1E000000

1B480000 1B5B4800

1E000000

1B5B4800

Cursor Right

0C000000

1B430000 1B5B3143

0C000000

1B5B0143

Syntax
DEF TERM ‘terminal’

Use
To configure HCD-E1 for using the control sequences corresponding to a
supported terminal, type:

DEF TERM 'terminal'

where 'terminal' stands for one of the types listed in the table above.
HCD-E1 performs the command and displays the date and the time
followed by the HCD-E1 prompt.

Note

If you enter DEF TERM (without the terminal type), HCD-E1 will reset to 0 all

the three codes.

DSP ALM

Purpose

Display the contents of the local unit alarm buffer. This buffer can contain
up to 100 alarms.

Syntax
DSP ALM[Option]

Use

To display the complete contents of the buffer, type:

DSP ALM

*To display the complete buffer contents and then clear the ON-type
alarms, type:

DSP ALM/C

*To display the complete buffer and then clear all the stored alarms,
type:

DSP ALM/CA

* See the description of CLR ALM command earlier in this chapter for

explanation of what the “clear” action means.