beautypg.com

RAD Data comm HCD-E1 User Manual

Page 45

background image

HCD-E1 Installation & Operation Manual

Chapter 1 - Introduction

01/01/01 08:07

Technical Specifications

1-27

E1 Sublink

Receive Timing

Always recovered from the E1 sublink receive
data signal

Transmit Timing

(user-selectable)

Follows the transmit timing of the HDSL link.

Synchronous Data

Channels

- DCE timing mode: HCD-E1 data channel

provides transmit and receive clocks for the
DTE connected to the data port.

- DTE1 timing mode: HCD-E1 data channel

sends the receive data accompanied by the
receive clock, derived from the main system
clock, to the DTE connected to the data
port, and accepts data from DTE according
to the DTE transmit clock.

- DTE2 timing mode: HCD-E1 data channel

transmits and receives data according to the
clock signals provided by the equipment
connected to the data port. (not available on
channels with X.21 interface).

Supervisory Port

Interface

V.24/ RS-232, asynchronous DCE interface for
direct connection of control terminal or
dial-up modem

Data Rate

300, 1200, 2400, 4800, 9600 bps, with
Autobaud option

Word Format

- One start bit
- 7 or 8 data bits
- Parity: none, odd, or even
- One stop bit

Connector

9-pin D-type, female

Alarm Relay

Function

Floating pair of NO and NC contacts

Contact Ratings

Open-circuit: maximum 60 VDC
Short-circuit: maximum 0.25A

Physical

Depth

243 mm / 9.5 in

Width

215 mm / 8.5 in

Height

43.7 mm / 1.75 in (1 U)

Weight

1.5 kg / 3.5 lb