RAD Data comm HCD-E1 User Manual
Page 120

Chapter 4 - Control from the Supervisory Port
HCD-E1
Installation & Operation Manual
4-36
HCD-E1 Command Set Description
11/01/00 19:23
DSP R HDR TST
Purpose
Display the results of the last hardware test performed by the unit located at
the remote end of the HDSL link (during power-on self-test or regular
operation).
Syntax
DSP R HDR TST
Use
• To display the hardware test report, type
DSP R HDR TST
Display Format
The display shows NO HARDWARE FAILURE if everything checks good, or
displays the appropriate message from the following list:
•
EPROM FAILURE
•
I/O EXP. FAILURE
•
HDSL FRAMER FAILURE
•
TRANSCEIVER FAILURE
After the message, HCD-E1 displays the date and time, followed by the
HCD-E1 prompt.
DSP R HDSL PM
Purpose
Display the contents of the performance monitoring registers of the
appliance located at the remote end of the HDSL link.
For an explanation of the HDSL performance monitoring registers, refer to
Section 5-3.
Syntax
DSP R HDSL PM [LPX] [Option]
Use
•
To display the performance monitoring registers of HDSL line 1 of the
remote unit, type:
DSP R HDSL PM LP1
or
DSP R HDSL PM
•
To display the performance monitoring registers of HDSL line 2 of the
remote unit, type:
DSP R HDSL PM LP2