RAD Data comm HCD-E1 User Manual
Page 110

Chapter 4 - Control from the Supervisory Port
HCD-E1
Installation & Operation Manual
4-26
HCD-E1 Command Set Description
11/01/00 19:23
6. When done, press
followed by the HCD-E1 prompt.
Note
1. You will have to perform steps 3 and 4 only in the case you have selected
USER in the MAP_TYPE field. Otherwise HCD-E1 selects the time slots
automatically.
2. If you have selected SEQ, make sure that the sum of START_TS and
NUM_OF_TS does not exceed 32.
3. If you have selected ALT, make sure that
NUM_OF_TS*2 + START_TS
≤ 31.
DEF SP
Purpose
Define the control port parameters. See Section 3-4 for parameters
description and practical guidelines on their selection.
Syntax
DEF SP
Use
1. Type:
DEF SP
2. The first page of the control port parameters data form is displayed. A
typical form is shown below. The form presents the current parameter
values as defaults.
SPEED
DATA
PARITY
INTERFACE
CTS
DCD_DEL
DSR
AUTO
8
NO
DCE
=RTS
0 MS
ON
3. Change the parameter values, using the spacebar to move between the
fields and pressing F or B to scroll among the available selections.
4. When done, press
parameters. A typical form is shown below.
POP_ALM
PWD
LOG_OFF
AUXILIARY DEVICE
NO
NO
NO
TERMINAL
5. Repeat the procedure given in step 3 above to select new parameter
values.
After the desired parameter values are selected, press
HCD-E1 displays the date and time, followed by the HCD-E1 prompt.
Parameters Programmable from the Terminal
In addition to the parameters listed in Section 3-4, the following parameters
can be programmed from the terminal only.