Chapter 4 - Control from the Supervisory Port

HCD-E1

Installation & Operation Manual

4-26

HCD-E1 Command Set Description

11/01/00 19:23

6. When done, press to finish. HCD-E1 displays the date and time

followed by the HCD-E1 prompt.

Note

1. You will have to perform steps 3 and 4 only in the case you have selected

USER in the MAP_TYPE field. Otherwise HCD-E1 selects the time slots

automatically.

2. If you have selected SEQ, make sure that the sum of START_TS and

NUM_OF_TS does not exceed 32.

3. If you have selected ALT, make sure that

NUM_OF_TS*2 + START_TS

31.

DEF SP

Purpose

Define the control port parameters. See Section 3-4 for parameters
description and practical guidelines on their selection.

Syntax
DEF SP

Use
1. Type:

DEF SP

2. The first page of the control port parameters data form is displayed. A

typical form is shown below. The form presents the current parameter
values as defaults.

SPEED

DATA

PARITY

INTERFACE

CTS

DCD_DEL

DSR

AUTO

8

NO

DCE

=RTS

0 MS

ON

3. Change the parameter values, using the spacebar to move between the

fields and pressing F or B to scroll among the available selections.

4. When done, press to display the next page of control port

parameters. A typical form is shown below.

POP_ALM

PWD

LOG_OFF

AUXILIARY DEVICE

NO

NO

NO

TERMINAL

5. Repeat the procedure given in step 3 above to select new parameter

values.

After the desired parameter values are selected, press to end.
HCD-E1 displays the date and time, followed by the HCD-E1 prompt.

Parameters Programmable from the Terminal
In addition to the parameters listed in Section 3-4, the following parameters
can be programmed from the terminal only.