beautypg.com

RAD Data comm HCD-E1 User Manual

Page 158

background image

Chapter 5 - Troubleshooting and Diagnostics

HCD-E1

Installation & Operation Manual

5-18

Performance Diagnostics Data

01/01/01 08:15

Background block error ratio (BBER)

The ratio of BBE to the total seconds in the current 15-minute interval
(not displayed on the LCD).

Current seconds (SECS)

The number of seconds in the current measurement interval. A
measurement interval has 900 seconds (15 minutes).

Note

This register is called “CURRENT TIMER” on the control terminal.

The same parameters are also available over 24-hour intervals (long-term
statistics
).

Summary of HDSL
Performance
Monitoring

Table 5-4 gives a summary of the performance diagnostics data displayed
under HDSL DIAG: LINE1 or HDSL DIAG: LINE2 on the HCD-E1 front
panel.

Table 5-4 Summary of HDSL Performance Monitoring from the Front Panel

Display

Description

Range

CURR ES

Number of ES measured during the current 15-minute interval. The
display is updated every second.

0 - 900

CURR UAS

Number of UAS measured during the current 15-minute interval. The
display is updated every second.

0 - 900

CURR SES

Number of SES measured during the current 15-minute interval. The
display is updated every second.

0 - 900

CURR BBE

Number of BBE measured during the current 15-minute interval. The
display is updated every second.

0 - 900

CURR SECS
(CURRENT TIMER on
the terminal)

The time in seconds that expired from the start of the current 15-minute
interval. The display is updated every second.

0 - 900

L.TERM ES

Number of ES measured during the current 24-hour interval. The
display is updated every 15 minutes.

0 - 65535

L.TERM UAS

Number of UAS measured during the current 24-hour interval. The
display is updated every 15 minutes.

0 - 65535

L.TERM SES

Number of SES measured during the current 24-hour interval. The
display is updated every 15 minutes.

0 - 65535

L.TERM BBE

Number of BBE measured during the current 24-hour interval. The
display is updated every 15 minutes.

0 - 65535

L.TERM INT

The number of 15-minute intervals that expired from the start of the
current 24-hour interval. The display is updated every 15 minutes.

0 - 96