Connecting the Control Port
If you are using the control terminal, connect a cable prepared in
accordance with Appendix B between the control port connector,
designated CONTROL DCE (see Figure 3-1 in Chapter 3), and the control
terminal. If the control terminal is connected via modems, use a cross-over
cable.

Note

The various interface cables should be shielded, in order to comply with FCC

rules. HCD-E1 and its data interfaces will work well even if the cables are not

shielded, but some radio interference may occur.

Connecting the
Power

To connect the power to HCD-E1, refer to the appropriate section below,
depending on your version of the unit (AC or DC).

Warning

Before switching on this instrument and connecting any other cable, the

protective earth terminals of this instrument must be connected to the

protective ground conductor of the mains power cord. If you are using

an extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or

outside the instrument) or disconnecting the protective earth terminal

can make this instrument dangerous. Intentional interruption is

prohibited.
For AC version, make sure that only fuses of the required rating, as

marked on the rear panel, are used for replacement. Do not use

repaired fuses or short-circuit the fuse holder. Always disconnect the

mains cable before removing or replacing the fuse. Whenever it is likely

that the fuse protection has been damaged, make the unit inoperative

and secure it against unintended operation.

AC Power Connection
AC power should be supplied to the HCD-E1 through the 5 ft (1.5m)
standard power cable terminated by a standard 3-prong plug
(see Figure 2-5). The cable is provided with the unit.
1. Check that the ON/OFF switch on the HCD-E1 rear panel is set to OFF.
2. First, connect the power cable to the connector on the HCD-E1 rear

panel, and then to the mains outlet.

DC Power Connection
To connect DC power to HCD-E1, refer to DC Power Supply Connection

Supplement.