HCD-E1 Command Set Description

4-51

To activate

Type

BERT test on data channel X of HCD-E1

In-band loopback on data channel X of the remote unit

Local (L) loopback on the HDSL lines (only from the unit
configured as central)

Local (L) loopback on data channel X of local HCD-E1

Remote (R) loopback on data channel X of local HCD-E1

Remote (R) loopback on data channel X of remote unit

Local (L) loopback on the E1 sublink of the local HCD-E1

Remote (R) loopback on the E1 sublink of the local
HCD-E1
Remote (R) loopback on the E1 sublink of the remote unit
Local loopback on H-RPT (only from the unit configured as
central)

LOOP BERT CH X, or LP BERT CH X*

LOOP INBAND CH X, or LP INBAND CH X*

LOOP L LINE, or LP L LINE

LOOP L CH X, or LP L CH X*

LOOP R CH X, or LP R CH X*

LOOP R R CH X, or LP R R CH X*

LOOP L SL, or LP L SL

LOOP R SL, or LP R SL

LOOP R R SL, or LP R R SL
LOOP L HRPT, or LP L HRPT

HCD-E1 performs the requested command and displays the date and time,
followed by the HCD-E1 prompt.

RESET

Purpose

Reset HCD-E1. This command causes HCD-E1 to initialize, therefore the
traffic through HCD-E1 will be disrupted until HCD-E1 returns to normal
operation.

Syntax
RESET

Use

To reset HCD-E1, type:

RESET