HCD-E1 Installation & Operation Manual

Chapter 5 - Troubleshooting and Diagnostics

01/01/01 08:15

Status Indications and Alarms 5-11

Table 5-2 HCD-E1 Alarm Buffer Messages (Cont.)

Alarm Message

Alarm
Number

Cause

Corrective Actions

Alarm
Type

HRPT_NTU SYNC LOSS:LP1
HRPT_NTU SYNC LOSS:LP2

04

Loss of synchronization on the
specified HDSL line at the NTU
side of H-RPT.

1. Check the corresponding HDSL line.
2. Perform a self-test on the unit configured as central and

replace the unit if it fails the self-test.

3. Replace H-RPT.

ON/OFF

HRPT_SELF TEST ERROR

05

A problem has been detected
during the cyclic H-RPT self-test.

Replace H-RPT.

ON

HRPT_LTU CRC ALM: LP1
HRPT_LTU CRC ALM: LP2

06

A CRC-6 error has been detected
in the input signal of the specified
HDSL line.

If the number of CRC-6 errors is significant (more than a few
errors per hour), perform the following:
1. Check the appropriate HDSL line from the H-RPT to the

unit configured as remote.

2. Perform a self-test on the unit configured as remote and

replace the unit if it fails the self-test.

3. Replace H-RPT.

ON

HRPT_NTU CRC ALM: LP1
HRPT_NTU CRC ALM: LP2

07

A CRC-6 error has been detected
in the input signal of the specified
HDSL line.

If the number of CRC-6 errors is significant (more than a few
errors per hour), perform the following:
1. Check the HDSL lines to the remote unit.
2. Perform a self-test on the unit configured as central and

replace the unit if it fails the self-test.

3. Replace H-RPT.

ON

HRPT ALARM BUFFER OVERFLOW

08

More than 100 alarms entries
have been written in the H-RPT
alarm buffer since the last clear
command. New alarms are
overwriting the older alarms.

Read the messages and then clear the buffer by sending the
CLR ALM HRPT/A command from the control terminal.

ON/OFF

.