Response format – Paradyne 4200 User Manual
Page 95
4. DS1 Facility Commands
4200-A2-GB20-00
August 2002
4-3
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ED-T1:[tid]:aid_ds1:[ctag]:::[ds1_nblk]:[pst] */
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-T1:[tid]:aid_ds1:[ctag]:::[ds1_nblk]:[pst] */
aid:ERRCDE=errcde
/* error description */
;
[ds1_nblk]
(continued)
For the following parameters if no value is specified, null is assumed.
ATMACCPROF: ATM Access Profile index (1). This value determines
the range of values for vpi and vci in several other commands. The
value cannot be changed while any VPLs or VCLs exist.
ATMACCPROFNM: ATM Access Profile name. The default is LT
DEFVAL.
QOSCLASS: Quality of service of connections on this port. The valid
value is UBR (UBR connections only).
[pst]
Desired state. Valid values are:
– IS: In service
– OOS: Out of service. OOS-MA (out of service, management) is
implied.
If no value is specified, this parameter remains unchanged.
Table 4-1.
ED-T1 Command Parameters (2 of 2)
ED-T1:[tid]:aid_ds1:[ctag]:::[ds1_nblk]:[pst];