13. Synchronization Commands

13-6

August 2002

4200-A2-GB20-00

RTRV-SYNCN

The RTRV-SYNCN Command retrieves the configuration of the reference source
for synchronization of the NE clock.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */

aid_syncn::[syncn_nblk];

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */
errcde
;

Table 13-5.

RTRV-SYNCN Command Parameters

RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

[aid_syncn]

AID of the NE clock. The value is CLKSRCNT.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.