Rtrv-syncn, Response format – Paradyne 4200 User Manual
Page 260
13. Synchronization Commands
13-6
August 2002
4200-A2-GB20-00
RTRV-SYNCN
The RTRV-SYNCN Command retrieves the configuration of the reference source
for synchronization of the NE clock.
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */
aid_syncn::[syncn_nblk];
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */
errcde
;
Table 13-5.
RTRV-SYNCN Command Parameters
RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:];
Restrictions: All parameters in this command are position-defined.
[tid]
Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
[aid_syncn]
AID of the NE clock. The value is CLKSRCNT.
[ctag]
Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.