Paradyne 4200 User Manual
Page 124
5. ATM Commands
5-14
August 2002
4200-A2-GB20-00
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf][sstf]
*/
errcde
;
Table 5-12. RTRV-ATMPORT Response Parameters
Parameter Explanation
tid Target
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code
aid_atmport
As described for command parameters (see
RTRV-ATMPORT Command Parameters
).
state
State from the Bellcore model. Values are:
IS-NR. In service, normal.
OOS-AU: Out of service, autonomous.
OOS-MA: Out of service, management. Transient state (changes to
OOS-AUMA).
OOS-AUMA: Out of service, autonomous and management.
sstf
As described for command parameters (see
RTRV-ATMPORT Command Parameters
).
atmport_nblk
SEGID: ATM segment location ID. A 16-octet field that identifies this
ATM interface for OAM F5 loopbacks. When a segment F5 OAM
loopback cell is received, the destination segment location in the cell is
compared to the segment location ID for the card. If the destination
location ID matches the location ID or is all ones, the cell is looped back
to the source. If there is not a match, the cell passes through the card.
The value is entered as 32 hexadecimal characters or ALLONES
(default). Allowed values are restricted per ITU-T1.610 as follows:
T
The first byte must be 01, 02, 03, FF or 6A.
T
If the first octet is FF, then octets 2
−
16 must also be FF.
T
If the first octet is 6A, then octets 2
−
16 must also be 6A.
If no value is specified for this field, then this parameter remains the
same.