beautypg.com

Rtrv-atur, Response format – Paradyne 4200 User Manual

Page 71

background image

3. ADSL Facility Commands

4200-A2-GB20-00

August 2002

3-35

RTRV-ATUR

The RTRV-ATUR command retrieves operational parameters configured for the
ADSL ATU-R.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-ATUR:[tid]:aid_atur:[ctag] */
aid_atur:atur_nblk
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-ATUR:[tid]:aid_atur:[ctag] */
errcde
;

Table 3-27. RTRV-ATUR Command Parameters

RTRV-ATUR:[tid]:aid_atur:[ctag];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_atur

Access identifier for an ADSL line. The value can be preceded with
AID=, but this is not required. Grouping and ranging are allowed. Enter
in the following format, replacing lower-case parameters with the values
given:

ATUR-rack-shelf-slot-circuit

rack: Rack number (1)

shelf: Shelf number (1)

slot: LT slot number (1)

circuit: ADSL circuit on the LT (1

24)

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.