8. IP Access Commands

8-12

August 2002

4200-A2-GB20-00

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ENT-IPPORT:[tid]:aid_ipport:[ctag]::cfg_mode:
ipport_nblk */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY;
/* ENT-IPPORT:[tid]:aid_ipport:[ctag]::cfg_mode:
ipport_nblk */
aid:ERRCDE=errcde
/* error description */
;

Table 8-10. ENT-IPPORT Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year (two digits), month, and day

hh:mm:ss

Hour (00-23), minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)