beautypg.com

Example, Related commands – Paradyne 4200 User Manual

Page 117

background image

5. ATM Commands

4200-A2-GB20-00

August 2002

5-7

Example

Edit rack 1, shelf 1, slot 1, circuit 9 to have an OAM segment location ID of all
ones.

ED-ATMPORT:TAMPA:LTATM-1-1-1-9:42:::SEGID=ALLONES

TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* ED-ATMPORT:TAMPA:LTATM-1-1-1-9:42:::SEGID=ALLONES */
;

Related Commands

RTRV-ATMPORT

on page 5-13

Table 5-6.

ED-ATMPORT Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

atmport_nblk

SEGID: ATM segment location ID. A 16-octet field that identifies this
ATM interface for OAM F5 loopbacks. When a segment F5 OAM
loopback cell is received, the destination segment location in the cell is
compared to the segment location ID for the card. If the destination
location ID matches the location ID or is all ones, the cell is looped back
to the source. If there is not a match, the cell passes through the card.

The value is entered as 32 hexadecimal characters or ALLONES
(default). Allowed values are restricted per ITU-T1.610 as follows:

T

The first byte must be 01, 02, 03, FF or 6A.

T

If the first octet is FF, then octets 2

16 must also be FF.

T

If the first octet is 6A, then octets 2

16 must also be 6A.

If no value is specified for this field, then this parameter remains the
same.