beautypg.com

Rept alm t1 – Paradyne 4200 User Manual

Page 100

background image

4. DS1 Facility Commands

4-8

August 2002

4200-A2-GB20-00

REPT ALM T1

The REPT ALM T1 message reports current T1 (DS1) facility alarms from the NE.

Table 4-6.

REPT ALM T1 Response Parameters

almcode atag REPT ALM T1 "aid_ds1:ntfncde,cond_ds1,
serveff,[ocrdat],[ocrtm],[locn],[dirn]:[cond_descr]";

almcde

Alarm code. Identifies the severity of the alarm. Values are:

*C: Critical alarm

**: Major alarm

*^: Minor alarm

A^: Automatic message (typically used to report a cleared alarm)

atag

Automatic tag that indicates the numerical sequence of messages
reported.

aid_ds1

Access identifier for an environment. Values are:

NTT1-circuit

– circuit: DS1 circuit in the NT (1)

ntfncde

Notification code. Values are:

CR: Critical alarm

MJ: Major alarm

MN: Minor alarm

CL: Cleared alarm

cond_ds1

DS1 facility condition. Values are:

ACTLPBK: Facility placed in loopback

AIS: Alarm indication signal

LCD: Loss of ATM cell delineation

LOF: Loss of framing

LOS: Loss of signal/clock

RAI: Remote alarm indication

serveff

Service effect. Values are:

SA: Service affecting

NSA: Not service affecting

[ocrdat]

Date of occurrence in the format: mm-dd (month and day)

[ocrtm]

Time of occurrence in the format: hh-mm (hour 0

23 and minute 0

59)

[locn]

Location of condition. The value is NEND (Near End).

[dirn]

Direction of condition. Values are:

RCV: Receive

TRMT: Transmit (for ACTLPBK)

[cond_descr]

Description of alarm condition (40 characters maximum).