Rtrv-pm-t1 – Paradyne 4200 User Manual
Page 104
![background image](/manuals/170876/104/background.png)
4. DS1 Facility Commands
4-12
August 2002
4200-A2-GB20-00
RTRV-PM-T1
The RTRV-PM-T1 command retrieves DS1 performance monitoring data.
Table 4-10. RTRV-PM-T1 Command Parameters (1 of 2)
RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],,
[tmper],[mondat],[montm];
Restrictions: All parameters in this command are position-defined.
[tid]
The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.
aid_ds1
Access identifier for the environment. Enter in the following format,
replacing lower-case parameters with the values given:
NTT1-circuit
– circuit: DS1 circuit on the NT (1)
[ctag]
The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.
[monds1]
Monitored parameter. Valid values are:
CV-L: Line code violations
ES-L: Line errored seconds
CV-P: Path coding violations
ES-P: Path errored seconds
ESB-P: Path errored seconds, type B (bursty errored seconds)
SES-P: Path severely errored seconds
UAS-P: Path unavailable seconds
SEFS-P: Path severely errored framing seconds
DHECV: Discarded cells due to HEC violation
Grouping is allowed. If no value is specified, ALL is assumed.
[monlev]
Threshold level. Valid values are:
lev-dirn
– lev: level (0
−
4294967295)
– dirn: direction. Values are UP and DN.
If no value is specified, 1-UP is assumed.
[locn]
Location of the facility. Valid values are:
NEND: Near end
FEND: Far end (not supported on G.703 interfaces)
If no value is specified, this parameter is not used for filtering
responses.
[tmper]
Time period. The only valid value is 15-MIN (15 minutes).