8. IP Access Commands

4200-A2-GB20-00

August 2002

8-9

ENT-ATMARPENT

The command ENT-ATMARPENT defines a new entry in the ATM Address
Resolution Protocol table in the NE.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
ENT-ATMARPENT:[tid]:aid_ipport:[ctag]::ip_addr,[vpi][vci] */
;

Table 8-7.

ENT-ATMARPENT Command Parameters

ENT-ATMARPENT:[tid]:aid_ipport:[ctag];;ip_addr,[vpi],[vci]
[arpent_nblk];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_ipport

Access identifier of the IP port to be deleted. The value can be
preceded with AID=, but this is not required. The valid values are:

ATM-1: First IP-over-ATM interface in the NT

ATM-2: Second IP-over-ATM interface in the NT

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

ip_addr

The next-hop IP address associated with the port. Valid values are:

ddd.ddd.ddd.ddd (where ddd is 1

255).

[vpi]

The ATM Virtual Path Identifier (0

15) associated with the virtual circuit

for the entry. If no value is specified, BOOTVPI is used on ATM-1.
Required for ATM-2. See

SET-NE-ALL

on page 14-31 for more

information.

[vci]

The ATM Virtual Channel Identifier (32

1023) associated with the

virtual circuit for the entry. If no value is specified, BOOTVCI is used on
ATM-1. Required for ATM-2. See

SET-NE-ALL

on page 14-31 for more

information.

[arpent_nblk]

The named parameter block for the ARP table. The block consists of
the following parameter followed by an equal sign (=) and a valid value:

BITRATE: Bandwidth associated with the ATM VC for the entry. The
valid value is 0 (UBR).