RTRV-INV-EQPT

The RTRV-INV-EQPT command retrieves inventory data associated with a unit of
equipment.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-INV-EQPT:[tid]:aid_eqpt:[ctag] */
aid_eqpt:cur_eqpt,manuf,partno,[rev],[serno],clei
;

Table 7-7.

RTRV-INV-EQPT Command Parameters

RTRV-INV-EQPT:[tid]:aid_eqps:[ctag];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_eqpts

Access identifier of an equipment unit. The value can be preceded with
AID=, but this is not required. Enter in one of the following formats,
replacing lower-case parameters with the values given:

NT: All Network Termination units

NTA Network Termination unit A

LT-rack-shelf-slot: All LT units in a shelf-slot

rack: Rack number (1)

shelf: Shelf number (1)

slot: LT slot number (1)

ATUR-rack-shelf-slot-circuit: ADSL endpoint attached to
LT-rack-shelf-circuit

LTA-rack-shelf-slot: Line Termination unit A (on main card)

LPCO-rack-shelf-slot: Low-Pass Filter-Central Office (in expansion slot)

SHELF-rack-shelf: General shelf and chassis-level information

Grouping is allowed. ALL may be used.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.