Response format, Example – Paradyne 4200 User Manual
Page 53
3. ADSL Facility Commands
4200-A2-GB20-00
August 2002
3-17
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ED-PROFILE-ADSLDNALM:[tid]:adsl_profile_id:[ctag]:::
[adslprof_nblk] */
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-PROFILE-ADSLDNALM:[tid]:adsl_profile_id:[ctag]:::
[adslprof_nblk] */
errcde
;
Example
Edit profile 6 to have an Errored Seconds threshold of 2.
ED-PROFILE-ADSLDNALM:TAMPA:6:42:::ES-L=2;
TAMPA 02-07-24 12:30:43
M 42 COMPLD
/* ED-PROFILE-ADSLDNALM:TAMPA:6:42:::ES-L=2; */
;
Table 3-14. ED-PROFILE-ADSLDNALM Response Parameters
Parameter Explanation
tid Target
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code