REPT-OPSTAT-T1

The REPT-OPSTAT-T1 command reports current operational parameters for T1
(DS1) lines.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* REPT-OPSTAT-T1:[tid]:aid_ds1:[ctag][:] */
;

Error Response

sid yy-mm-dd hh:mm:ss
M c DENY
/* REPT-OPSTAT-T1:[tid]:aid_ds1:[ctag][:] */
aid:ERRCDE=errcde
/* error description */
;

Table 4-8.

REPT-OPSTAT- T1 Command Parameters

REPT-OPSTAT-T1:[tid]:aid_dsl:[ctag][;];

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_ds1

Access identifier for a a DS1 facility. The value can be preceded with
AID=, but this is not required. Enter in the following format, replacing
lower-case parameters with the values given:

NTT1-circuit

– circuit: DS1 circuit in the NT (1)

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.