Response format – Paradyne 4200 User Manual
Page 228
![background image](/manuals/170876/228/background.png)
10. Fault Commands
10-36
August 2002
4200-A2-GB20-00
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-COND-EQPT:[tid]:aid_eqpt:[ctag]::[cond_eqpt] */
"aid_eqpt,[aid_type]:[ntfncde],cond_eqpt,serveff,,,,,,{cond_
descr}"
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-COND-EQPT:[tid]:aid_eqpt:[ctag]::[cond_eqpt] */
errcde
;
Table 10-22. RTRV-COND-EQPT Response Parameters (1 of 2)
Parameter Explanation
tid Target
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code
aid_eqpt
As described for command parameters (see
RTRV-COND-EQPT Command Parameters
), except ALL is not used.
aid_type
The type of Access Identifier. The value is EQPT.
[ntfncde]
Notification code. Valid values are:
CR: Critical alarm
MJ: Major alarm
MN: Minor alarm
NA: Not alarmed (reported via REPORT EVENT)