Example, Related command – Paradyne 4200 User Manual
Page 251
12. Security Commands
4200-A2-GB20-00
August 2002
12-13
Example
Retrieve the configuration data for the local console interface.
RTRV-CID-SECU:TAMPA:CRAFT:42;
TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* RTRV-CID-SECU:TAMPA:CRAFT:42 */
;
"CRAFT:SUPER,MXINV=3,
TMOUT=10"
Related Command
Table 12-12. RTRV-CID-SECU Response Parameters
Parameter Explanation
tid
Target NE identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
cid
As described for command parameters (see
RTRV-CID-SECU Command Parameters
), except that ALL is not used
chap
Channel Access Privilege. Access privilege is not assigned per channel,
so the highest user privilege is displayed.
[cid_nblk]
Named parameter block for CID. The block consists of one or more of
the following parameters, each followed by an equal sign and a value.
MXINV: Maximum number of invalid logon alerts before declaring an
intrusion alert (3).
TMOUT: Timeout interval (in minutes) for a user session (0
−
99). If the
user is idle for this long, the session is automatically terminated. A value
of 0 disables the feature.
errcde
Error code (see