Rtrv-cond-all – Paradyne 4200 User Manual
Page 223
10. Fault Commands
4200-A2-GB20-00
August 2002
10-31
RTRV-COND-ALL
The RTRV-COND-ALL command retrieves the condition of NE alarm indicators.
Table 10-19. RTRV-COND-ALL Command Parameters (1 of 2)
RTRV-COND-ALL:[tid]:aid_all:[ctag]::[cond_all],[locn],
[dirn];
RESTRICTIONS: All parameters in this command are position-defined.
[tid]
The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.
aid_all
Access Identifier for all entities. The value is ALL.
[ctag]
The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.
[cond_all]
Condition. Values are:
ACTLPBK: Facility placed in loopback.
AIS: Alarm Indication Signal
EQPT: Equipment failed self-test
FACTERM: Modem could not initialize
FANALAM-1: Alarm for Fan 1.
FANALAM-2: Alarm for Fan 2.
LCD: Loss of ATM Cell Delineation
LCD-F: Loss of Cell Delineation (Fast)
LOF: Loss Of Frame
LOL: Loss Of Link
LOS: Loss Of Signal/clock
LPR: Loss Of Power
PROGVER: Failed to load or find requested software
RAI: Remote Alarm Indication
RMTDLFAIL: Failed to download software
SWROLLBACK: Software version rolled back
[locn]
Location of the condition. Valid values are:
NEND: Near End
FEND: Far End
Only applicable to conditions supporting location. If no value is
specified, ALL is assumed.