RTRV-COND-ALL

The RTRV-COND-ALL command retrieves the condition of NE alarm indicators.

Table 10-19. RTRV-COND-ALL Command Parameters (1 of 2)

RTRV-COND-ALL:[tid]:aid_all:[ctag]::[cond_all],[locn],
[dirn];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.

aid_all

Access Identifier for all entities. The value is ALL.

[ctag]

The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.

[cond_all]

Condition. Values are:

ACTLPBK: Facility placed in loopback.

AIS: Alarm Indication Signal

EQPT: Equipment failed self-test

FACTERM: Modem could not initialize

FANALAM-1: Alarm for Fan 1.

FANALAM-2: Alarm for Fan 2.

LCD: Loss of ATM Cell Delineation

LCD-F: Loss of Cell Delineation (Fast)

LOF: Loss Of Frame

LOL: Loss Of Link

LOS: Loss Of Signal/clock

LPR: Loss Of Power

PROGVER: Failed to load or find requested software

RAI: Remote Alarm Indication

RMTDLFAIL: Failed to download software

SWROLLBACK: Software version rolled back

[locn]

Location of the condition. Valid values are:

NEND: Near End

FEND: Far End

Only applicable to conditions supporting location. If no value is
specified, ALL is assumed.