6. Cross Connect Commands

6-4

August 2002

4200-A2-GB20-00

ED-CRS-VC

The ED-CRS-VC command edits the configuration of a VC-level cross-connection
between the NT and an LT.

Table 6-3.

ED-CRS-VC Command Parameters

ED-CRS-VC:[tid]:nt_vcl,lt_vcl:[ctag]::::[pst];

RESTRICTIONS: The following restrictions apply to this command:

T

All parameters in this command are position-defined.

T

This command requires two AID parameter entries to uniquely identify an existing
cross-connection.

T

The deletion of a cross-connection is conditional on its current operational state. All
endpoints must be edited OOS-MA-AS or the command will fail.

T

A partial (PRTL) response is generated if all cross-connections cannot be deleted.

T

The range of values for vpi and vci is determined by the number of VPI and VCI bits
allocated.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

nt_vcl

Virtual Channel Identifier for the Virtual Channel Link on the NT
(network) side. Grouping and ranging are allowed. Enter in the following
format, replacing lower-case parameters with the values given:

NTVCL-vpi-vci

– vpi: Virtual Path Identifier

– vci: Virtual Channel Identifier for the Virtual Channel Link

lt_vcl

Virtual Channel Identifier for the Virtual Channel Link on the LT (user)
side. Grouping and ranging are allowed.

Enter in the following format, replacing lower-case parameters with the
values given:

LTVCL-rack-shelf-slot-circuit-vpi-vci: LT circuit

– rack: Rack number (1)

– shelf: Shelf number (1)

– slot: LT slot number (1)

– circuit: ADSL circuit on the LT (1

4)

– vpi: Virtual Path Identifier (for LT vpi=0, for NT vpi=0

15)

– vci: Virtual Channel Identifier for the Virtual Channel Link (for LT

vpi=32

63, for NT vpi=32

1023)

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

[pst]

Desired Primary State. Valid values are:

IS: In-Service

OOS: Out-Of-Service (OOS-MA is implied)

If not specified, the value of this parameter remains unchanged.