14. System Commands

14-6

August 2002

4200-A2-GB20-00

CANC-USER

The CANC-USER command logs off a user’s own session.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* CANC-USER:[tid]:[uid]:[ctag] */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* CANC-USER:[tid]:[uid]:[ctag] */
errcde
;

Table 14-5.

CANC-USER Command Parameters

CANC-USER:[tid]:[uid]:[ctag];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a factory
default value of null. The NE's SID code is the only other valid value.

[uid]

The user identification name (10 characters maximum). Input is
case-sensitive.

[ctag]

The correlation tag (6 characters maximum) that links an input
command with associated output responses. It is optional with a default