10. Fault Commands

10-32

August 2002

4200-A2-GB20-00

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
RTRV-COND-ALL:[tid]:aid_all:[ctag]::[cond_all],[locn],[dirn]
*/
"aid,[aid_type]:ntfncde,cond,[serveff],,,[locn],[dirn],,
[cond_descr]"
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/*
RTRV-COND-ALL:[tid]:aid_all:[ctag]::[cond_all],[locn],[dirn]
*/
errcde
;

[dirn]

Direction of the condition. Valid values (for conditions supporting
direction):

RCV: Receive

TRMT: Transmit

If no value is specified, ALL is assumed.

Table 10-19. RTRV-COND-ALL Command Parameters (2 of 2)

RTRV-COND-ALL:[tid]:aid_all:[ctag]::[cond_all],[locn],
[dirn];

Table 10-20. RTRV-COND-ALL Response Parameters (1 of 2)

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed