10. Fault Commands
4200-A2-GB20-00
August 2002
10-35
RTRV-COND-EQPT
The RTRV-COND-EQPT command retrieves the current condition of specified
equipment alarm indicators.
Table 10-21. RTRV-COND-EQPT Command Parameters
RTRV-COND-EQPT:[tid]:aidall_eqpt:[ctag]::[ntfcde],[cond_eqp
t];
RESTRICTIONS: All parameters in this command are position-defined.
[tid]
The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.
aid_eqpt
Access Identifier for a piece of equipment. The value can be preceded
with aid=, but this is not required. Grouping is allowed. Valid values are:
ALL: All equipment units
SHELF-rack-shelf
LT-rack-shelf-slot: All LT units in slot
LTA-rack-shelf-slot: LT unit A (main card)
rack: rack number (1)
shelf: shelf number (1)
slot: LT slot number (1)
Grouping is allowed. If no value is specified, ALL is assumed.
[ctag]
The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.
[cond_eqpt]
Equipment condition. Valid values are:
EQPT: Equipment failed self-test
FANALM-1: Fan alarm for Fan 1
FANALM-2: Fan alarm for Fan 2
PROGVER: Failed to load or find requested software
RMTDLFAIL: Failed to download software
SWROLLBACK: Software version rolled back
Grouping is allowed. If no value is specified, ALL is assumed.