Rtrv-adsl, Response format – Paradyne 4200 User Manual
Page 68
![background image](/manuals/170876/68/background.png)
3. ADSL Facility Commands
3-32
August 2002
4200-A2-GB20-00
RTRV-ADSL
The RTRV-ADSL command retrieves operational parameters configured for ADSL
lines.
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-ADSL:[tid]:aid_adsl:[ctag]::::[pstf] */
"aid_adsl:adsl_nblk:state"
;
Table 3-25. RTRV-ADSL Command Parameters
RTRV-ADSL:[tid]:aid_adsl:[ctag]::::[pstf],[sstf];
RESTRICTIONS: All parameters in this command are position-defined.
[tid]
Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
aid_adsl
Access identifier for an ADSL line. The value can be preceded with
AID=, but this is not required. Grouping and ranging are allowed. Enter
in the following format, replacing lower-case parameters with the values
given:
ADSL-rack-shelf-slot-circuit
rack: Rack number (1)
shelf: Shelf number (1)
slot: LT slot number (1)
circuit: ADSL circuit on the LT (1
−
24)
[ctag]
Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.
[pstf]
Primary state filter. Valid values are:
IS: Retrieve In-Service entities only
OOS: Retrieve Out-Of-Service entities only
Grouping is allowed. If no value is specified, this filter is ignored.
[sstf]
Secondary state filter. This filter is ignored.