beautypg.com

Rtrv-eqpt, Response format – Paradyne 4200 User Manual

Page 152

background image

7. Equipment Commands

7-6

August 2002

4200-A2-GB20-00

RTRV-EQPT

The RTRV-EQPT command retrieves configuration data associated with a unit of
equipment.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-EQPT:[tid]:aid_eqpts:[ctag] */
aid_eqpts:[eqpt_type],[cur_eqpt]:[eqpt_nblk]:state,[sst]

;

Table 7-5.

RTRV-EQPT Command Parameters

RTRV-EQPT:[tid]:aid_eqpts:[ctag][:];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_eqpts

Access identifier of an equipment unit. The value can be preceded with
AID=, but this is not required. Enter in one of the following formats,
replacing lower-case parameters with the values given:

– NT: All Network Termination units

– NTA Network Termination unit A

– LT-rack-shelf-slot: All LT units in a rack-shelf-slot

– rack: Rack number (1)

– shelf: Shelf number (1)

– slot: LT slot number (1)

– LTA-rack-shelf-slot: Line Termination unit A (on main card)

– LPCO-rack-shelf-slot: Low-Pass Filter-Central Office (in

expansion slot

Grouping is allowed. ALL may be used.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.